ArcGIS Desktop

  • ArcGIS Pro
  • ArcMap

  • My Profile
  • Help
  • Sign Out
ArcGIS Desktop

ArcGIS Online

The mapping platform for your organization

ArcGIS Desktop

A complete professional GIS

ArcGIS Enterprise

GIS in your enterprise

ArcGIS Developers

Tools to build location-aware apps

ArcGIS Solutions

Free template maps and apps for your industry

ArcGIS Marketplace

Get apps and data for your organization

  • Documentation
  • Support
Esri
  • Sign In
user
  • My Profile
  • Sign Out

ArcMap

  • Home
  • Get Started
  • Map
  • Analyze
  • Manage Data
  • Tools
  • Extensions

Schematic analyst—Find Connected trace task properties

  • Selection options
  • Flow direction options

When the Find Connected schematic analyst trace task is chosen in the Trace Task drop-down list, clicking the Trace Task Properties button Trace Task Properties opens its associated properties tab as follows:

Schematic Network Analyst Trace dialog box—Find Connected

Selection options

The choices in Selection options specify whether the schematic nodes and schematic links detected by the schematic analyst trace task will appear selected in the active schematic diagram at the end of the trace task operation.

  • Uncheck Select nodes if you don't want the schematic nodes detected by the Find Connected schematic analyst trace task to be selected.
  • Uncheck Select links if you don't want the schematic links detected by the Find Connected schematic analyst trace task to be selected.
    Note:

    If you check the Select links check box and you select schematic links in the active diagram so that these links are treated as barriers during the analysis trace task, those barrier links are removed from the resulting selection set at the end of the process, and only the schematic links detected by the trace task are selected.

The figures below show the results of the Find Connected schematic analyst trace task starting from a selected schematic node with or without barriers positioned on some schematic links.

  • Figure 1.1 represents the initial schematic diagram. The red schematic node is the only schematic feature selected in the schematic diagram.
  • Figure 1.2 shows the result of the Find Connected schematic analyst trace task starting from the red schematic node.
  • Figure 1.3 shows two selected schematic links in the diagram before the Find Connected schematic analyst trace task is performed. These links are interpreted as barriers during the analysis. The Find Connected trace task is performed from the red schematic node as in figure 1.1.
  • Figure 1.4 shows the result of the Find Connected schematic analyst trace task starting from the red schematic node. The barrier schematic links are no longer selected. The selected schematic features are only those returned by the schematic analyst trace task.
Find Connected—result without barriers
Find Connected—results with barriers

Flow direction options

The Flow direction options specify whether the Find Connected schematic analyst trace task must work with flow directions. Three types of analysis can be performed:

  • Searching for schematic features connected to a given schematic node without taking the flow direction on the network into account
  • Searching for schematic features that lie downstream from a given schematic node in the network
  • Searching for schematic features that lie upstream from a given schematic node in the network

  • Uncheck the Use flow check box if you want the Find Connected schematic analyst trace task to work without regard to flow direction. This is the default mode of searching.
  • Check Use flow if you want the flow direction to be taken into account during the analysis.

    When the Use flow option is checked, choose either of two options: Upstream if you want only schematic features that lie upstream from the specified schematic node to be detected, or Downstream if you want the analysis to detect schematic features that lie downstream from this schematic node.

    Note:

    When the flow is unknown and Use flow is checked, the analysis works on the direction of the schematic links using the origin and extremity nodes of the schematic links as they are specified in the schematic diagram.

The figures below show the result of the Find Connected trace task starting from a selected schematic node when the Use flow option is checked:

  • Figure 2.1 represents the initial schematic diagram. The red schematic node is the only schematic feature selected in the schematic diagram.
  • Figure 2.2 shows the result of the Find Connected schematic trace task starting from the red schematic node when the Downstream option is checked.
  • Figure 2.3 shows the result of the trace task when the Upstream option is checked.
Find Connected—results when Use Flow check box is checked

Related topics

  • Performing a schematic analyst trace task
  • Schematic analyst - Find Path trace task properties
  • Schematic analyst - Find Overlapping Links trace task properties
  • Schematic analyst - Find Loops trace task properties
  • Analyzing a schematic diagram

ArcGIS Desktop

  • Home
  • Documentation
  • Support

ArcGIS

  • ArcGIS Online
  • ArcGIS Desktop
  • ArcGIS Enterprise
  • ArcGIS
  • ArcGIS Developer
  • ArcGIS Solutions
  • ArcGIS Marketplace

About Esri

  • About Us
  • Careers
  • Esri Blog
  • User Conference
  • Developer Summit
Esri
Tell us what you think.
Copyright © 2021 Esri. | Privacy | Legal